MAX 50-100KTL3-X LV/MV is suitable for both commercial rooftop and ground mounted solar plants, the max series on-grid inverter was designed with up to 80kw big capacity. first quad-core inverter in the industry provides it fast processing capability to handle transient grid fault. with the extraordinary 6/7 MPP trackers, ensures high yields of the system.
| Datasheet | MAX 60KTL3 MV | MAX 70KTL3 MV | MAX 80KTL3 MV | MAX 90KTL3 MV | MAX 100KTL3 MV |
| Input data (DC) | |||||
| Max, recommended PV power(for module STC) | 90000W | 105000W | 120000W | 130000W | 130000W |
| Max. DC voltage | 1100V | 1100V | 1100V | 1100V | 1100V |
| Start voltage | 250V | 250V | 250V | 250V | 250V |
| Nominal voltage | 700V | 700V | 700V | 730V | 730V |
| Nominal voltage | 200V-1000V | 200V-1000V | 200V-1000V | 200V-1000V | 200V-1000V |
| No. of MPP trackers | 6 | 7 | 7 | 7 | 7 |
| No. of PV strings per MPP tracker | 2 | 2 | 2 | 2 | 2 |
| Max. input current per | 25A | 25A | 25A | 25A | 25A |
| MPP tracker | |||||
| Max, short-circuit currant per MPP tracker | 32A | 32A | 32A | 32A | 32A |
| Output data(AC) | |||||
| AC nominal power | 60000W | 70000W | 80000W | 90000W | 1000000W |
| Mcx. AC opporent power | 66600VA | 77700VA | 88800VA | 100000VA | 111000VA |
| Nominal AC voltage (range*) | 277W480V 425-540VAC | 277V/480V 425-540VAC | 277V/480V 425-540VAC | 288V/500V 425-540VAC | 288V/500V 425-540WC |
| AC grid frequency (range*) | 50/60 Hz (45-55Hz/55-65 Hz) | 50/60 Hz (45-55Hz/55-65 Hz) | 50/60 Hz (45-55Hz/55-65 Hz) | 50/60 Hz (45-55Hz/55-65 Hz) | 50/60 Hz (45-55Hz/55-65 Hz) |
| Max. output current | 80.2A | 93.6A | 107.0A | 115.7A | 128.6A |
| Adjustable power factor | 0.8leading …0.8lagging | 0.8leading …0.8lagging | 0.8leading …0.8lagging | 0.8leading …0.8lagging | 0.8leading …0.8lagging |
| THDi | <3% | <3% | <3% | <3% | <3% |
| AC grid connection type | 3W+PE | 3W+PE | 3W+PE | 3W+PE | 3W+PE |
| Efficiency | |||||
| Max. efficiency | 99.00% | 99.00% | 99.00% | 99.00% | 99.00% |
| European efficiency | 98.50% | 98.50% | 98.60% | 98.60% | 98.60% |
| MPPT efficiency | 99.90% | 99.90% | 99.90% | 99.90% | 99.90% |
| Datasheet | MAX 50KTL3LV | MAX 60KTL3LV | MAX 70KTL3LV | MAX 80KTL3LV |
| Input Data | ||||
| Max.recommended PV power (for module STC) | 65000W | 78000W | 91000W | 104000W |
| Max.DC voltage | 1100V | 1100V | 1100V | 1100V |
| Start Voltage | 250V | 250V | 250V | 250V |
| MPPT voltage range | 200V~1000V | 200V~1000V | 200V~1000V | 200V~1000V |
| Nominal voltage | 585V | 585V | 585V | 585V |
| Max.Input Current | 25A | 25A | 25A | 25A |
| Number of independent MPP trackers/strings per MPP tracker | 6/2 | 6/2 | 6/2 | 6/2 |
| Output(AC) | ||||
| Rated AC output power | 50000W | 60000W | 70000W | 80000W |
| MAx.AC apparent power | 55500VA | 66600VA | 77000VA | 88000VA |
| Max .output current | 80.5A | 96.6A | 112.7A | 128.8A |
| AC nominal voltage | 230V/400V | 230V/400V | 230V/400V | 230V/400V |
| AC grid frequency | 50HZ/60HZ,±5HZ | 50HZ/60HZ,±6HZ | 50HZ/60HZ,±7HZ | 50HZ/60HZ,±8HZ |
| Power factor | 0.8leading-0.8laging | 0.8leading-0.8laging | 0.8leading-0.8laging | 0.8leading-0.8laging |
| THDi | <3% | <3% | <3% | <3% |
| AC grid connection type | 3W+N+PE | 3W+N+PE | 3W+N+PE | 3W+N+PE |
| Efficiency | ||||
| Max.efficiency | 98.8%% | 98.80% | 99.00% | 98.80% |
| Euro-eta | 98.30% | 98.30% | 98.40% | 98.30% |
| MPPT efficiency | 99.90% | 99.90% | 99.90% | 99.90% |
SAFE & RELIABLE:
- String monitoring
- AC/DC Type II SPD
- IP65 protection rating

HIGH YIELDS:
- Maximum efficiency of 99%
- 6/7 MPPTs, 12/14 strings
- Wide working voltage
USER-FRIENDLY:
- Local WiFi+APP maintenance
- Smart diagnosis
- Online smart service